Industrial PROFIBUS to Fiber Optic Converter, Single-mode, ST connector, -40 to 75°C

Quantità':

Prezzo per pezzo

€ 1.438,58

(IVA esclusa)

€ 1.755,07 (IVA inclusa)

Prezzo di 1 pz. iva (22%) inclusa: € 1.755,07

Disponibilità: 20 gg lav

Brand: MOXA

SKU: 93308

Model: ICF-1280I-S-ST-T

Bisogno di aiuto?


Certificati

CE Certificato
FCC Certificato
UL Certificato
IEC Certificato
IECEX Certificato
ATEX Certificato
RoHS Certificato

Features and Benefits

  • Redundant fiber ring with zero recovery time
  • Examine network-wide fiber communication from a single converter
  • Auto baudrate detection and data speed up to 12 Mbps
  • PROFIBUS bus fail prevents corrupted datagram in functioning segment
  • Alarm by relay output
  • 2 kV galvanic isolation protection
  • Dual power inputs for redundancy
  • Extends PROFIBUS transmission distance up to 45 km
  • Wide temperature model available for -40 to 75°C environments

Introduction

The ICF-1280I series industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1280I provides 2 kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted. Optical fiber cables are often deployed for long distance communication and a fiber optic inspection pen is used by engineers to ensure proper communication quality of the fiber cable. The ICF-1280I series converters eliminate the need for a fiber optic inspection pen by providing a Remote Fiber Diagnosis function that uses DIP switch adjustments. There are two major functions provided by Remote Fiber Diagnosis: (1) determining which side (Tx or Rx) is causing the problem on the converter; (2) examining the fiber connections for the overall topology from any individual converter. Fiber cable abnormalities can be automatically detected and identified by the LED indicator even if it is not adjacent to the converter. Remote Fiber Diagnosis facilitates fiber cable deployment and management, and also significantly shortens troubleshooting time by examining fiber connections for the overall topology from any individual converter. The ICF-1280I series converters can connect PROFIBUS devices in a redundant fiber ring topology. Use the DIP switch to configure all the ICF- 1280I converters to Redundant Ring mode. When a PROFIBUS master transmits a signal from one converter to the PROFIBUS slave devices, this signal will travel to all the converters around the ring until it returns to the original converter and terminate. The redundant ring structure ensures no packet loss with zero recovery time. Electrical noise may be generated when a PROFIBUS device malfunctions or the serial interface fails, resulting in bus failure. Traditional media converters transmit noise signals through the fiber wire to the other converter. This not only disrupts data communication between the two buses, but will also bring communication across the entire system to a halt. When this occurs, the engineers will not be able to easily locate the failed device because the entire PROFIBUS network is down. To avoid this situation, the ICF-1280I series converter has a mechanism to detect and recognize noise signals. If the bus fails on one side, the noise signal will not propagate through the ICF-1280I converter and affect additional bus segments. In addition, the ICF-1280I converter will also trigger an alarm to provide the location of the failure to the field engineer. The ICF-1280I series converters simply convert the signal back and forth between PROFIBUS and fiber at baudrates between 9.6 Kbps to 12 Mbps. Engineers do not need to know the baudrate of the connected PROFIBUS device; the ICF-1280I series converters can automatically detect the baudrate of the PROFIBUS device and apply this baudrate directly. This is an extremely convenient feature. If necessary, baudrates can be set to a fixed value via DIP switches to shorten the baudrate detection period when the system initializes. The ICF-1280I series converter provides a fiber link monitoring function to detect the communication errors on both sides of the fiber connection and determine which side (Tx or Rx) is causing the problem. When a communication error occurs, a red LED status indicator will turn on and the relay alarm will activate. If a fiber abnormality is occurred in a remote fiber segment, the Fault LED will flash to indicate the abnormality is happened in remote segment. Engineers can use the fiber test function for troubleshooting.

Technology

Standard: IEC 61158-2 for PROFIBUS DP 

Interface

P1/P2 Port: ST optical fiber
P3 Port: PROFIBUS DP (DB9 female)
Relay Alarm: One relay output with current carrying capacity of 2 A @ 30 VDC (Normal open)
LED Indicators: PWR1, PWR2, Ready, P1, P2, P3, Fault
DIP Switches: 
     DIP 1 to 4: Baudrate setting
     DIP 5: Fiber link monitor
     DIP 6 to 7: Linear/Star mode (w/ optional P1/P2 disable), Redundant Ring mode
     DIP 8: Remote Fiber Diagnosis

PROFIBUS Communication

Data Rate: 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, and 12000 Kbps
Auto Baudrate: Yes
Isolation Protection: 2 kV

Optical Fiber Side

Point-to-Point, Linear (Bus), Star, Redundant Topologies:
     Multi-mode:
          Wavelength: 820 nm
          Tx Output: -14 dBm
          Rx Sensitivity: -28 dBm
          Link Budget: 14 dBm
          Typical Distance: 4 km
     Single-mode:
          Wavelength: 1310 nm
          Tx Output: -7 dBm
          Rx Sensitivity: -29 dBm
          Link Budget: 21 dBm
          Typical Distance: 45 km

Physical Characteristics

Housing: Metal
Mounting: DIN-Rail mounting, wall mounting (with optional kit)
Dimensions: 39 x 115 x 70 mm (1.54 x 4.53 x 2.76 in)
Weight: 225 g

Environmental Limits

Operating Temperature: 
     Standard Models: 0 to 60°C (32 to 140°F)
     Wide Temp. Models: -40 to 75°C (-40 to 167°F)
     Storage Temperature: -40 to 75°C (-40 to 167°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)

Power Requirements

Input Voltage: 12 to 48 VDC
Power Consumption: 315 mA @ 12 V
Connector: Terminal Block
Power Line Protection: Level 3 (2 kV) Surge Protection
Over Current Protection: 1.1 A

Standards and Certifications

Safety: UL 508, EN 60950-1
Hazardous Location: UL/cUL Class I Division 2 Groups A/B/C/D (Pending), ATEX Zone 2 EEx nC IIC (Pending), IECEx (Pending)
EMC: CE, FCC Part 15 Subpart B Class A
EMI: EN 55022, Class A; EN 55024
EMS: 
     EN 61000-4-2 (ESD) Level 3,
     EN 61000-4-3 (RS) Level 3,
     EN 61000-4-4 (EFT) Level 3,
     EN 61000-4-5 (Power Surge) Level 3,
     EN 61000-4-5 (Communication Surge) Level 3,
     EN 61000-4-6 (CS) Level 3
Freefall: IEC 60068-2-32
Green Product: RoHS, CRoHS, WEEE

Warranty

Warranty Period: 5 years

Disclaimer

Sei interessato a un Preventivo ?

Hai una azienda e sei interessato ad un grosso acquisto di merce?
Contattaci per avere una offerta Personalizzata

Clicca qui

I Nostri Marchi

Distribuiamo Moxa
Distribuiamo Takachi
Distribuiamo Planet
Distribuiamo Patlite
Distribuiamo Digitus
Distribuiamo Mean Well
Distribuiamo 3onedata
Distribuiamo Advantech
Distribuiamo Sirio Antenne

Resta collegato... iscriviti alla Newsletter

Visita anche il nostro portale icpdas.store

© 2020. Lastella Trade

site by www.davidesantandrea.it & Lastella Trade