FGSD-1008HPS Planet Managed POE

FGSD-1008HPS Planet

FGSD-1008HPS Planet

FGSD-1008HPS

8-Port 10/100TX 802.3at PoE + 2-Port Gigabit TP/SFP Combo Managed Ethernet Switch (125W)

Quantità':

Prezzo per pezzo

€ 146,65

(IVA esclusa)

€ 178,91 (IVA inclusa)

Prezzo di 1 pz. iva (22%) inclusa: € 178,91

Disponibilità: 10 gg lav

Brand: PLANET

SKU: 115286

Model: FGSD-1008HPS

Bisogno di aiuto?


 PLANET’s newly-revised FGSD-1008HPS Layer 2 PoE+ Managed Switch is designed for enterprises and industries where a network of PDs can be centrally managed. The Switch’s management functions have been enhanced to include intelligent PoE management, IPv6 management, ACL, GVRP, and more.
 
Cost-optimized Managed PoE+ Switch with L2/L4 Switching and Security

PLANET FGSD-1008HPS is an ideal Managed PoE+ Switch which provides cost-effective advantage to local area network and is widely accepted in the SMB office network. It offers intelligent Layer 2 data packet switching and management functions, friendly web user interface and stable operation. The model complies with IEEE 802.3at Power over Ethernet Plus (PoE+) at an affordable price; the FGSD-1008HPS is equipped with 8 10/100BASE-TX Fast Ethernet ports and 2 Gigabit TP/SFP combo interfaces with inner power system. With its 8 Fast Ethernet ports integrated with 802.3at PoE+ injector function and total power budget of up to 125 watts, it offers a rack-mountable, affordable, safe and reliable power solution for SMBs deploying Power over Ethernet networks, or requiring enhanced data security and network traffic management.
 
Intelligent LED Indicator for Real-time PoE Usage

The FGSD-1008HPS helps users to monitor the current status of PoE power usage easily and efficiently with its advanced LED indication. Called “PoE Power Usage” found on the front panel of the FGSD-1008HPS Layer 2 PoE+ Managed Switch, it has four orange LEDs indicating the range of the current PoE power usage.
 
Solution for IPv6 Networking

With the support for IPv6/IPv4 protocol, and easy and friendly management interfaces, the FGSD-1008HPS is the ideal choice for IP surveillance, VoIP and wireless service providers to connect with the IPv6 network. It also helps SMBs to step in the IPv6 era with the lowest investment and without having to replace the network facilities even though ISPs establish the IPv6 FTTx edge network.
 
Built-in Unique PoE Functions for Surveillance Management

As a managed PoE Switch for surveillance network, the FGSD-1008HPS features the following intelligent PoE management functions:

  • Real-time Display of PoE Chipset Temperature 
  • PD Alive Check
  • PoE Port Sequence
  • PoE Schedule

 
Intelligent Powered Device Alive Check

The FGSD-1008HPS can be configured to monitor a connected PD status in real time via ping action. Once the PD stops working and it is without response, the FGSD-1008HPS will resume the PoE port power and bring the PD back to work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source, thus reducing administrator management burden.
 
PoE Port Sequence 

To prevent all the PoE ports of the FGSD-1008HPS from being active at the same time when the Switch has booted up, the PoE ports of the FGSD-1008HPS can be configured to allow each port to be activated at an interval time. In addition, the “Delay” setting is to delay power feeding on each port when the FGSD-1008HPS has completely booted up.
 
PoE Schedule for Energy Saving

Besides being used for IP surveillance, the FGSD-1008HPS is certainly applicable to build any PoE network including VoIP and wireless LAN. Under the trend of energy saving worldwide and contributing to the environmental protection on the Earth, the FGSD-1008HPS can effectively control the power supply besides its capability of giving high watts power. The “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs and enterprises save energy and budget.
 
Robust Layer 2 Features

The FGSD-1008HPS can be programmed for advanced switch management functions, such as Multiple Spanning Tree Protocol (MSTP), BPDU filtering, BPDU Guard, dynamic port link aggregation, IGMP/MLD snooping, DHCP relay agent, loop detection and GVRP, voice VLAN and the Link Layer Discovery Protocol (LLDP). The Layer 2 protocol included is to help discover basic information about neighboring devices in the local broadcast domain. Other features included are the port-based/802.1Q VLAN and Q-in-Q VLAN, Layer 2/4 QoS, port mirroring, broadcast storm control and bandwidth control.
 
Enhanced Security and Traffic Control

The FGSD-1008HPS offers the comprehensive Layer 2 to Layer 4 access control list (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP/MAC address or defined typical network applications. The FGSD-1008HPS also provides DHCP Snooping, ARP Inspection and MAC Verification functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. Also included are per port MAC/IP address binding and MAC address binding.  The network administrator can now build highly-secure corporate networks with considerably less time and effort than before.
 
Cybersecurity Network Solution to Minimize Security Risks

The cybersecurity features that virtually need no effort and cost to have included the protection of the switch management and the enhanced security of the mission-critical network. Both SSH and SSL protocols are utilized to provide strong protection against advanced threats. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.
 
Efficient Management

For efficient management, the FGSD-1008HPS is equipped with Web, Telnet and SNMP management interfaces. With the built-in Web-based management interface, the FGSD-1008HPS offers an easy-to-use, platform-independent management and configuration facility. By supporting the standard Simple Network Management Protocol (SNMP), the FGSD-1008HPS can be managed via any standard management software. For text-based management, the switch can be accessed via Telnet. Moreover, the FGSD-1008HPS offers secure remote management by supporting SNMPv3 connections which encrypt the packet content at each session.
 
Flexible and Extendable Uplink Solution

The FGSD-1008HPS provides 2 extra Gigabit TP/SFP combo interfaces supporting 10/100/1000BASE-T RJ45 copper to connect with surveillance network devices such as NVR, Video Streaming Server or NAS to facilitate surveillance management. Or through these fiber SFP slots occupied by the 1000BASE-SX/LX SFP (small form-factor pluggable) fiber transceivers, it can be uplinked to a backbone switch and monitoring center in long distance. The distance can be extended from 550 meters to 2km (multi-mode fiber) to 10/20/40/80/120 kilometers (single-mode fiber or WDM fiber). They are well-suited for applications within the industrial data centers and distributions.

Specifications

Hardware Specifications
Copper Ports: 8 10/100BASE-TX RJ45 Auto-MDI/MDI-X ports
PoE Injector Port: 8 802.3af/802.3at PoE+ injector ports
Gigabit Copper Ports: 2 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports
SFP/mini-GBIC Slots: 2 1000BASE-X SFP interfaces, shared with Port-9 to Port-10
Switch Architecture: Store-and-Forward
Switch Fabric: 5.6Gbps/non-blocking
Switch Throughput@64bytes: 4.16Mpps @64bytes
MAC Address Table: 16K entries
Shared Data Buffer: 4Mb
Flow Control: IEEE 802.3x pause frame for full duplex
Back pressure for half duplex
Maximum Transmit Unit: 1522 bytes
Reset Button: < 5 sec: System reboot
> 5 sec: Factory default
LED: System:
 Power (Green)
10/100TX RJ45 Interfaces (Port 1 to Port 8):
 LNK/ACT (Green), PoE-in-Use (Orange)
10/100/1000BASE-T RJ45 / SFP Interfaces (Port 9 to Port 10):
 LNK/ACT (Green), 1000 (Green)
PoE Usage:
 30W, 60W, 90W, 120W (Orange)
Thermal Fan: 1
Power Requirements: 100~240V AC, 50/60Hz, 2A (max.)
Power Consumption/Dissipation: Max.150watts/511BTU
Dimensions (W x D x H): 330 x 155 x 43.5 mm
Weight: 1.5kg
Enclosure: Metal
 
Power over Ethernet
PoE Standard: IEEE 802.3af Power over Ethernet/PSE
IEEE 802.3at Power over Ethernet Plus/PSE
PoE Power Supply Type: End-span
Power Pin Assignment: 1/2(+), 3/6 (-)
PoE Power Output: Per Port 52V DC, 300mA. Max. 15.4 watts (IEEE 802.3af)
Per Port 52V DC, 600mA. Max. 36 watts (IEEE 802.3at)
PoE Power Budget: 125 watts
Number of PDs, 7 watts: 8
Number of PDs, 15.4 watts: 8
Number of PDs, 30 watts: 4
 
Layer 2 Functions
Port Mirroring: TX/RX/both
Many-to-1 monitor
VLAN: Port-based VLAN, up to 10 VLAN groups
IEEE 802.1Q tagged VLAN
- Up to 256 VLAN groups, out of 4094 VLAN IDs
Protocol VLAN
Provider Bridging (VLAN Q-in-Q) support (IEEE 802.1ad)
GVRP
Voice VLAN
Link Aggregation: IEEE 802.3ad LACP supports one 2-port trunk group; static trunk supports one 2-port trunk group
Spanning Tree Protocol: IEEE 802.1D Spanning Tree Protocol (STP)
IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)
STP BPDU filtering, BPDU Guard
IGMP Snooping: IPv4 IGMP snooping v1/ v2 and v3
MLD Snooping: IPv6 MLD snooping v1, v2
Access Control List: IPv4/IPv6 IP-based ACL
MAC-based ACL
QoS: Ingress/Egress Rate Limit per port bandwidth control
Storm Control support
- Broadcast/ Multicast /DLF (Destination Lookup Failure)/ARP/ICMP
Traffic classification
- IEEE 802.1p Qos/CoS
- TCP/UDP/DSCP/IP precedence of IPv4/IPv6 packets
Strict priority and Weighted Round Robin (WRR) CoS policies
Security: Access Control List
- IPv4/IPv6 IP-based ACL
- MAC-based ACL
Port-MAC-IP Address Binding
- Port-MAC-IP Port Setting
- Port-MAC-IP Entry Setting
MAC Address Binding
- Static MAC
- MAC Filtering
DHCP snooping to filter distrusted DHCP messages
ARP Inspection discards ARP packets with invalid MAC address to IP address binding
 
Management Functions
Basic Management Interfaces: IPv4 and IPv6 dual stack management
Switch management interface
- Web switch management
- Telnet command line interface
- SNMP v1, v2c and v3
BOOTP and DHCP for IP address assignment
System maintenance
- Firmware upgrade via HTTP
- Configuration upload/download through web interface
- Hardware-based reset button for system reset to factory default
SNTP Network Time Protocol
Link Layer Discovery Protocol (LLDP)
Event message logging to remote Syslog server
PLANET smart discovery utility
Secure Management Interfaces: SNMP v3, SSH, SSL
 
Standards Conformance
Regulatory Compliance: FCC Part 15 Class A, CE
Standards Compliance: IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3z Gigabit SX/LX
IEEE 802.3ab Gigabit 1000T
IEEE 802.3x flow control and back pressure
IEEE 802.3ad port trunk with LACP
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
IEEE 802.1s Multiple Spanning Tree Protocol
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN tagging
IEEE 802.1ab LLDP
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
RFC 2068 HTTP
RFC 1112 IGMP version 1
RFC 2236 IGMP version 2
RFC 3376 IGMP version 3
RFC 2710 MLD version 1
RFC 3810 MLD version 2
 
Environment
Operating: Temperature: 0 ~ 50 degrees C
Relative Humidity: 5 ~ 95% (non-condensing)
Storage: Temperature: -10 ~ 70 degrees C
Relative Humidity: 5 ~ 95% (non-condensing)

Disclaimer

Sei interessato a un Preventivo ?

Hai una azienda e sei interessato ad un grosso acquisto di merce?
Contattaci per avere una offerta Personalizzata

Clicca qui

I Nostri Marchi

Distribuiamo Moxa
Distribuiamo Takachi
Distribuiamo Planet
Distribuiamo Patlite
Distribuiamo Digitus
Distribuiamo Mean Well
Distribuiamo 3onedata
Distribuiamo Advantech
Distribuiamo Sirio Antenne

Resta collegato... iscriviti alla Newsletter

Contattaci via email: clicca qui

Visita anche il nostro portale icpdas.store

© 2020. Lastella Trade

site by www.davidesantandrea.it & Lastella Trade