Features and Benefits

  • Fiber cable test function validates fiber communication
  • Auto baudrate detection and data speed up to 12 Mbps
  • PROFIBUS bus fail prevents corrupted datagram in functioning segment
  • Fiber inverse feature
  • Alarm by relay output
  • 2 kV galvanic isolation protection
  • Dual power inputs for redundancy (Reverse power protection)
  • Extends PROFIBUS transmission distance up to 45 km
  • Wide temperature model available for -40 to 75°C environments

Introduction

The ICF-1180I series industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1180I provides 2 kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted. Fiber-optic cables are usually deployed for long distance communication. To ensure proper communication across the fiber-optic cables, engineers use fiber sensors. With fiber cable test function through DIP switch adjustments, the ICF-1180I series converters eliminate the need to rely on fiber-optic sensors. This function not only detects fiber communication abnormalities but also validates the format of the received packet. It can also determine which side (Tx or Rx) is causing the problem. When the PROFIBUS device malfunctions or the serial interface fails, it will generate electrical noise, resulting in bus failure. Traditional media converters will let the noise signal pass through the fiber and on to the other converter. This will disrupt data transmissions between the two buses and eventually communication ceases across the entire system. When this occurs, the engineer will not be able to easily locate the failed device because the entire PROFIBUS network is down. To avoid this situation, the ICF-1180I was designed to detect and recognize noise signals. If the bus fails on one side, the noise signal will not propagate through the ICF-1180I and affect additional bus segments. In addition, the ICF-1180I will also trigger an alarm notification to the field engineer on the location of the failure.

Technology

Standards: IEC 61158-2 for PROFIBUS DP

Interface

P1 Port: ST optical fiber
P2 Port: PROFIBUS DP (DB9 female)
Relay Alarm: One relay output with current carrying capacity of 2 A @ 30 VDC (Normal open)
LED Indicators: PWR1, PWR2, Ready, P1 Status, P2 Status
DIP Switches: 
     DIP 1 to 4: Baudrate setting
     DIP 5: Fiber link monitor
     DIP 6: Fiber inverse function
     DIP 7: Reserved
     DIP 8: Fiber cable test function

PROFIBUS Communication

Data Rate: 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, and 12000 kbps
Auto Baudrate: Yes
Isolation Protection: 2 kV

Optical Fiber Side

Point-to-Point Transmission:
     Multi-mode:
          Wavelength: 820 nm
          Tx Output: -14 dBm
          Rx Sensitivity: -28 dBm
          Link Budget: 14 dBm
          Typical Distance: 4 km
     Single-mode:
          Wavelength: 1310 nm
          Tx Output: -7 dBm
          Rx Sensitivity: -29 dBm
          Link Budget: 21 dBm
          Typical Distance: 45 km

Physical Characteristics

Housing: Metal
Mounting: DIN-Rail mounting, wall mounting (with optional kit)
Dimensions: 30.3 x 115 x 70 mm (1.19 x 4.53 x 2.76 in)
Weight: 180 g

Environmental Limits

Operating Temperature: 
     Standard Models: 0 to 60°C (32 to 140°F)
     Wide Temp. Models: -40 to 75°C (-40 to 167°F)
     Storage Temperature: -40 to 75°C (-40 to 167°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)

Power Requirements

Input Voltage: 12 to 48 VDC
Power Consumption: 186 mA @ 12 V
Connector: Terminal Block
Power Line Protection: Level 3 (2 kV) Surge Protection
Over Current Protection: 1.1 A

Standards and Certifications

Safety: UL 508, EN 60950-1
Hazardous Location: UL/cUL Class I Division 2 Groups A/B/C/D (Pending), ATEX Zone 2 EEx nC IIC (Pending), IECEx (Pending)
EMC: CE, FCC Part 15 Subpart B Class A
EMI: EN 55022, Class A; EN 55024
EMS:
     EN 61000-4-2 (ESD) Level 3,
     EN 61000-4-3 (RS) Level 3,
     EN 61000-4-4 (EFT) Level 3,
     EN 61000-4-5 (Power Surge) Level 3,
     EN 61000-4-5 (Communication Surge) Level 3,
     EN 61000-4-6 (CS) Level 3
Freefall: IEC 60068-2-32
Green Product: RoHS, CRoHS, WEEE

Warranty

Warranty Period: 5 years

Disclaimer

Sei interessato a un Preventivo ?

Hai una azienda e sei interessato ad un grosso acquisto di merce?
Contattaci per avere una offerta Personalizzata

Clicca qui

I Nostri Marchi

Distribuiamo Moxa
Distribuiamo Takachi
Distribuiamo Planet
Distribuiamo Patlite
Distribuiamo Digitus
Distribuiamo Mean Well
Distribuiamo 3onedata
Distribuiamo Advantech
Distribuiamo Sirio Antenne

Resta collegato... iscriviti alla Newsletter

Visita anche il nostro portale icpdas.store

© 2020. Lastella Trade

site by www.davidesantandrea.it & Lastella Trade