EDR-150-24
AC-DC DIN rail power supply 150W, input voltage range 90-264VAC, output 24VDC 6.5A
Bisogno di aiuto?
Applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical apparatus
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- EN61000-6-2(EN50082-2) industrial immunity level
- 100% full load burn-in test
- 2 years warranty
Specifications
OUTPUT
DC VOLTAGE: 24V
RATED CURRENT: 6.5A / 230VAC 5.2A / 115VAC
CURRENT RANGE: 0 ~ 6.5A / 230VAC 0 ~ 5.2A / 115VAC
RATED POWER: 156W / 230VAC 125W / 115VAC
RIPPLE & NOISE (max.): 150mVp-p
VOLTAGE ADJUSTMENT RANGE: 24 ~ 28V
VOLTAGE TOLERANCE: ±1.0%
LINE REGULATION: ±0.5%
LOAD REGULATION: ±1.0%
SETUP, RISE TIME: 1500ms, 60ms/230VAC 3000ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.): 16ms/230VAC 10ms/115VAC at full load
INPUT
VOLTAGE RANGE: 90 ~ 264VAC
FREQUENCY RANGE: 47 ~ 63Hz
EFFICIENCY (Typ.): 87%
AC CURRENT (Typ.): 2.6A/115VAC 1.7A/230VAC
INRUSH CURRENT (Typ.): 20A/115VAC 35A/230VAC
LEAKAGE CURRENT: <1mA / 240VAC
PROTECTION
OVERLOAD:
105 ~ 130% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed / 230VAC
105 ~ 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed / 115VAC
OVER VOLTAGE: 29 ~ 33V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE: Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.: -20 ~ +60°C (Refer to "Derating Curve")
WORKING HUMIDITY: 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY: -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT: ±0.03%/°C (0 ~ 50°C)
VIBRATION: Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC
SAFETY STANDARDS: Ul508, TUV EN60950-1 approved;(meet EN60204-1)
WITHSTAND VOLTAGE: I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION: Compliance to EN55032 (CISPR32) Class A, EN61000-3-2, Class A (≦80% Load), EN61000-3-3
EMC IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF: 472.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSIONS: (WxHxD) 40 x 125.2 x 113.5 mm