SDR-960-24 Mean Well Alimentatori Guida DIN

SDR-960-24 Mean Well

SDR-960-24

AC-DC slim Industrial DIN rail power supply, PFC Function, input voltage range 180-264VAC, output 960W 24VDC 40A

Quantità':

Prezzo per pezzo

€ 353,21

(IVA esclusa)

€ 430,92 (IVA inclusa)

Prezzo di 1 pz. iva (22%) inclusa: € 430,92

Disponibilità: 10 gg lav

Brand: MEAN WELL

SKU: 116020

Model: SDR-960-24

Line: Input Voltage Range 180-264VAC

Bisogno di aiuto?


Features

  • AC input 180~264VAC only
  • 130% peak load capability
  • 110mm slim design
  • Built-in active PFC function compliance to EN61000-3-2
  • High efficiency 94% and low power dissipation
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Can be installed on DIN rail TS-35/7.5 or 15
  • UL508(industrial control equipment)approved
  • EN61000-6-2(EN50082-2) industrial immunity level
  • Current sharing up to 3840W(3+1)
  • Built-in DC OK relay contact
  • 100% full load burn-in test
  • 3 years warranty

Specifications

OUTPUT

DC VOLTAGE: 24V
RATED CURRENT: 40A
CURRENT RANGE: 0 ~ 40A
RATED POWER: 960W
PEAK CURRENT: 52A
PEAK POWER: 1248W (3 sec.)
RIPPLE & NOISE (max.): 180mVp-p
VOLTAGE ADJUSTABLE RANGE: 24 ~ 28V
VOLTAGE TOLERANCE: ±1.0%
LINE REGULATION: ±0.5%
LOAD REGULATION: ±1.0%
SETUP, RISE TIME: 1000ms, 100ms/230VAC at full load
HOLD UP TIME (Typ.): 14ms / 230VAC at full load

INPUT

VOLTAGE RANGE: 180 ~ 264VAC
FREQUENCY RANGE: 47 ~ 63Hz
POWER FACTOR (Typ.): PF≧0.95/230VAC at full load 
EFFICIENCY (Typ.): 94%
AC CURRENT (Typ.): 6A/230VAC
INRUSH CURRENT (Typ.): COLD START 50A / 230VAC
LEAKAGE CURRENT: <3.5mA / 240VAC

PROTECTION

OVERLOAD: Normally works within 105 ~ 130% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery after 30 seconds if the peak load condition is removed
Constant current  limiting within 130 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage, re-power on to recover
 
OVER VOLTAGE: 29 ~ 33V 
Protection type: Shut down o/p voltage, with auto-recovery or re-power on to recover
 
OVER TEMPERATURE: Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

DC OK REALY CONTACT RATINGS (max.): 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load

ENVIRONMENT

WORKING TEMP.: -30 ~ +70°C (Refer to "Derating Curve")
WORKING HUMIDITY: 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY: -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT: ±0.03%/°C (0 ~ 50°C)
VIBRATION: Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
 
SAFETY & EMC
SAFETY STANDARDS: UL508, TUV EN62368-1, BSMI CNS14336-1, AS/NZS 62368.1, EAC TP TC 004,  approved ; (meet EN60204-1)
WITHSTAND VOLTAGE: I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC     O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION: Compliance to EN55032 (CISPR32), EN61204-3 Conduction Class B,  Radiation class A, EN61000-3-2,-3, EAC TP TC 020, BSMI CNS13438
EMC IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, EAC TP TC 020
 
MTBF: 69.8K hrs min.      MIL-HDBK-217F (25℃)
DIMENSIONS: (WxHxD) 110 x 125.2 x 150 mm

Disclaimer

Sei interessato a un Preventivo ?

Hai una azienda e sei interessato ad un grosso acquisto di merce?
Contattaci per avere una offerta Personalizzata

Clicca qui

I Nostri Marchi

Distribuiamo Moxa
Distribuiamo Takachi
Distribuiamo Planet
Distribuiamo Patlite
Distribuiamo Teltonika
Distribuiamo Digitus
Distribuiamo Mean Well
Distribuiamo 3onedata
Distribuiamo Advantech
Distribuiamo Sirio Antenne

Resta collegato... iscriviti alla Newsletter

Visita anche il nostro portale icpdas.store

© 2020. Lastella Trade

site by www.davidesantandrea.it & Lastella Trade